Chelsea, London SW5 < Back

Kensington and Chelsea Chimney lining

The flue serving the ground floor flat, which serves an open gas fire, was breached. This meant that there was a very real danger of carbon monoxide leaking into other properties.

After calculating the opening size of the fireplace, existing flue dimensions, and height of the property, it was clear that stainless steel was not able to achieve an adequate cross sectional area of flue. Furanflex BLACK was chosen. A 22 metre x 275mm liner was installed in a single day with minimal mess. The flue now performs properly, and a 25 year guarantee and HETAS certificates were issued on completion of the contract.